<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ICECAT-interface SYSTEM "https://data.icecat.biz/dtd/ICECAT-interface_response.dtd">
<!--source: Icecat.biz 2026-->
<!--Language ID: 10-->
<!--Version: v2-->
<ICECAT-interface xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://data.icecat.biz/xsd/ICECAT-interface_response.xsd">
 <Product Code="1" HighPic="https://images.icecat.biz/img/norm/high/8157604-251.jpg" HighPicHeight="764" HighPicSize="192165" HighPicWidth="1200" ID="8157604" LowPic="https://images.icecat.biz/img/norm/low/8157604-251.jpg" LowPicHeight="127" LowPicSize="25916" LowPicWidth="200" Name="GS110TP" IntName="GS110TP" LocalName="" Pic500x500="https://images.icecat.biz/img/norm/medium/8157604-251.jpg" Pic500x500Height="318" Pic500x500Size="53322" Pic500x500Width="500" Prod_id="GS110TP-100NAS" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/thumbs/8157604.jpg" ThumbPicSize="2777" Title="NETGEAR GS110TP Gerenciado Power over Ethernet (PoE)" GeneratedIntTitle="NETGEAR GS110TP" GeneratedLocalTitle="NETGEAR GS110TP Gerenciado Power over Ethernet (PoE)" BrandLocalTitle="">
  <CategoryFeatureGroup ID="31974" No="0">
   <FeatureGroup ID="0">
    <Name ID="1351220" langid="10" Value="Características técnicas"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="763" No="195">
   <FeatureGroup ID="12">
    <Name ID="1351203" langid="10" Value="Portas e interface"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1144" No="135">
   <FeatureGroup ID="14">
    <Name ID="1351205" langid="10" Value="Dimensões e peso"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1142" No="150">
   <FeatureGroup ID="27">
    <Name ID="1351218" langid="10" Value="Energia"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1143" No="140">
   <FeatureGroup ID="28">
    <Name ID="1351219" langid="10" Value="Condições de operação"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2987" No="165">
   <FeatureGroup ID="34">
    <Name ID="1351223" langid="10" Value="Protocolos"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1141" No="190">
   <FeatureGroup ID="35">
    <Name ID="1351224" langid="10" Value="Networking"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2484" No="180">
   <FeatureGroup ID="62">
    <Name ID="87440" langid="10" Value="Transmissão de dados"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2483" No="125">
   <FeatureGroup ID="67">
    <Name ID="1351253" langid="10" Value="Dados da embalagem"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2482" No="175">
   <FeatureGroup ID="75">
    <Name ID="1351261" langid="10" Value="Segurança"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="41469" No="0">
   <FeatureGroup ID="76">
    <Name ID="1351262" langid="10" Value="Certificações"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2944" No="200">
   <FeatureGroup ID="93">
    <Name ID="1351277" langid="10" Value="Recursos de gestão"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="49104" No="130">
   <FeatureGroup ID="116">
    <Name ID="78861" langid="10" Value="Conteúdo da embalagem"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="5713" No="185">
   <FeatureGroup ID="137">
    <Name ID="1351313" langid="10" Value="Fibra ótica"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53530" No="0">
   <FeatureGroup ID="143">
    <Name ID="1351319" langid="10" Value="Bateria"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8343" No="144">
   <FeatureGroup ID="146">
    <Name ID="1351322" langid="10" Value="Outros recursos"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10881" No="160">
   <FeatureGroup ID="148">
    <Name ID="630466" langid="10" Value="Design"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="9999" No="145">
   <FeatureGroup ID="174">
    <Name ID="1351344" langid="10" Value="PoE"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10882" No="155">
   <FeatureGroup ID="184">
    <Name ID="1351352" langid="10" Value="Desempenho"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="70398" No="0">
   <FeatureGroup ID="185">
    <Name ID="1351353" langid="10" Value="Características"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="24990" No="-100">
   <FeatureGroup ID="198">
    <Name ID="5915533" langid="10" Value="Dados logísticos"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="60022" No="0">
   <FeatureGroup ID="232">
    <Name ID="5915565" langid="10" Value="Máquina de café"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="27921" No="170">
   <FeatureGroup ID="252">
    <Name ID="5915583" langid="10" Value="Uso"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="76178" No="120">
   <FeatureGroup ID="279">
    <Name ID="7574484" langid="10" Value="Sustentabilidade"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="77984" No="0">
   <FeatureGroup ID="305">
    <Name ID="8849033" langid="10" Value="Pegada de carbono"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="258">
   <Name ID="5743093" langid="10" Value="Switches de rede"/>
  </Category>
  <EANCode/>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy/>
  <BulletPoints/>
  <GeneratedBulletPoints>
   <GeneratedBulletPoint Value="Gerenciado" langid="10" No="1"/>
   <GeneratedBulletPoint Value="Suporte Quality of Service (QoS)" langid="10" No="2"/>
   <GeneratedBulletPoint Value="Números de portas ethernet Basic switching RJ-45: 8" langid="10" No="3"/>
   <GeneratedBulletPoint Value="1000BASE-TX, 100BASE-TX, 10BASE-T" langid="10" No="4"/>
   <GeneratedBulletPoint Value="Tabela de endereços MAC: 4000 entradas" langid="10" No="5"/>
   <GeneratedBulletPoint Value="48v, 1.25A Power over Ethernet (PoE)" langid="10" No="6"/>
  </GeneratedBulletPoints>
  <ProductBundled/>
  <ProductDescription/>
  <ProductFeature Localized="0" ID="106352236" Local_ID="0" Value="Managed" CategoryFeature_ID="20904" CategoryFeatureGroup_ID="2944" No="10100150" Optional="0" Presentation_Value="Gerenciado" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Gerenciado">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3769">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1354604" langid="10" Value="Tipo de switch"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352238" Local_ID="0" Value="Y" CategoryFeature_ID="18587" CategoryFeatureGroup_ID="2944" No="100010" Optional="0" Presentation_Value="Sim" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sim">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3242">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1336932" langid="10" Value="Suporte Quality of Service (QoS)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352239" Local_ID="0" Value="8" CategoryFeature_ID="86090" CategoryFeatureGroup_ID="763" No="10100100" Optional="0" Presentation_Value="8" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="8">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13503">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1343615" langid="10" Value="Números de portas ethernet Basic switching RJ-45"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352242" Local_ID="0" Value="2" CategoryFeature_ID="20894" CategoryFeatureGroup_ID="763" No="100060" Optional="1" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3759">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1337272" langid="10" Value="Quantidade de slots SFP/SFP+"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="214868137" Local_ID="0" Value="2" CategoryFeature_ID="152578" CategoryFeatureGroup_ID="763" No="100060" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="24681">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5935639" langid="10" Value="Quantidade de entradas de módulos SFP"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="262981273" Local_ID="0" Value="DC-in jack" CategoryFeature_ID="242403" CategoryFeatureGroup_ID="763" No="99000" Optional="0" Presentation_Value="Tomada de entrada CC" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Tomada de entrada CC">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="25745">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5935641" langid="10" Value="Conector de poder"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352235" Local_ID="0" Value="IEEE 802.3ab,IEEE 802.3af,IEEE 802.3i,IEEE 802.3u,IEEE 802.3x,IEEE 802.3z" CategoryFeature_ID="45644" CategoryFeatureGroup_ID="1141" No="100999" Optional="0" Presentation_Value="IEEE 802.3ab, IEEE 802.3af, IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="IEEE 802.3ab, IEEE 802.3af, IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1802">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1335775" langid="10" Value="Padrões de rede"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352229" Local_ID="0" Value="N" CategoryFeature_ID="42644" CategoryFeatureGroup_ID="1141" No="100998" Optional="0" Presentation_Value="N" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="N">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7364">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1339822" langid="10" Value="Suporte 10G"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352240" Local_ID="0" Value="1000BASE-TX,100BASE-TX,10BASE-T" CategoryFeature_ID="2027" CategoryFeatureGroup_ID="1141" No="100099" Optional="0" Presentation_Value="1000BASE-TX, 100BASE-TX, 10BASE-T" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1000BASE-TX, 100BASE-TX, 10BASE-T">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7659">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1340075" langid="10" Value="Tecnologia de cabeamento de fibra de cobre"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352224" Local_ID="0" Value="Y" CategoryFeature_ID="2042" CategoryFeatureGroup_ID="1141" No="100002" Optional="0" Presentation_Value="Sim" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sim">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="536">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1334948" langid="10" Value="Transmissão full duplex"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="107505573" Local_ID="0" Value="Y" CategoryFeature_ID="16314" CategoryFeatureGroup_ID="1141" No="100000" Optional="0" Presentation_Value="Sim" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sim">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2756">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1336518" langid="10" Value="Controle de fluxo"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352234" Local_ID="0" Value="64" CategoryFeature_ID="33014" CategoryFeatureGroup_ID="1141" No="99997" Optional="0" Presentation_Value="64" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="64">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6567">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1339247" langid="10" Value="Número de VLANs"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352230" Local_ID="0" Value="4000" CategoryFeature_ID="2026" CategoryFeatureGroup_ID="2484" No="10100086" Optional="0" Presentation_Value="4000 entradas" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="4000">
    <Measure ID="56">
     <Signs>
      <Sign ID="11361" langid="11"><![CDATA[entradas]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="566">
    <Measure ID="56" Sign="">
     <Signs>
      <Sign ID="11361" langid="11"><![CDATA[entradas]]></Sign>
     </Signs>
    </Measure>
    <Name ID="513498" langid="10" Value="Tabela de endereços MAC"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352226" Local_ID="0" Value="10/100/1000 Mbps" CategoryFeature_ID="2029" CategoryFeatureGroup_ID="2484" No="100999" Optional="1" Presentation_Value="10/100/1000 Mbps" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10/100/1000 Mbps">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="606">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1334990" langid="10" Value="Taxa de transferência de dados suportada"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="107505578" Local_ID="0" Value="Y" CategoryFeature_ID="20896" CategoryFeatureGroup_ID="2484" No="100080" Optional="0" Presentation_Value="Sim" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sim">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3760">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="42440" langid="10" Value="Store-and-forward"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352223" Local_ID="0" Value="1" CategoryFeature_ID="8769" CategoryFeatureGroup_ID="2484" No="100022" Optional="1" Presentation_Value="1 Gbit/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="68">
     <Signs>
      <Sign ID="45545" langid="10"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="3188">
    <Measure ID="68" Sign="">
     <Signs>
      <Sign ID="45545" langid="10"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1336887" langid="10" Value="Taxa máxima de transferência de dados"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352231" Local_ID="0" Value="Y" CategoryFeature_ID="18591" CategoryFeatureGroup_ID="2484" No="100020" Optional="0" Presentation_Value="Sim" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sim">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3246">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1336936" langid="10" Value="Suporte para Jumbo frames"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352232" Local_ID="0" Value="DHCP client" CategoryFeature_ID="307220" CategoryFeatureGroup_ID="2482" No="100055" Optional="0" Presentation_Value="DHCP client" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="DHCP client">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="38476">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5935683" langid="10" Value="Características de DHCP"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352233" Local_ID="0" Value="Y" CategoryFeature_ID="33011" CategoryFeatureGroup_ID="2482" No="100001" Optional="0" Presentation_Value="Sim" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sim">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6565">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="223496" langid="10" Value="IGMP snooping"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352247" Local_ID="0" Value="N" CategoryFeature_ID="18590" CategoryFeatureGroup_ID="10881" No="10100111" Optional="0" Presentation_Value="N" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="N">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3245">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1336935" langid="10" Value="Empilhável"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352260" Local_ID="0" Value="LAN,Status" CategoryFeature_ID="7916" CategoryFeatureGroup_ID="10881" No="100079" Optional="0" Presentation_Value="LAN, Status" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="LAN, Status">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1501">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1335560" langid="10" Value="Indicadores LED"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352252" Local_ID="0" Value="cUL IEC 950/EN 60950, CB, CE" CategoryFeature_ID="2039" CategoryFeatureGroup_ID="10881" No="99902" Optional="1" Presentation_Value="cUL IEC 950/EN 60950, CB, CE" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="cUL IEC 950/EN 60950, CB, CE">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="607">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="78934" langid="10" Value="Segurança"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352251" Local_ID="0" Value="157004" CategoryFeature_ID="7920" CategoryFeatureGroup_ID="10882" No="99980" Optional="0" Presentation_Value="157004 h" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="157004">
    <Measure ID="46">
     <Signs>
      <Sign ID="1576" langid="10"><![CDATA[h]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="533">
    <Measure ID="46" Sign="">
     <Signs>
      <Sign ID="1576" langid="10"><![CDATA[h]]></Sign>
     </Signs>
    </Measure>
    <Name ID="44851" langid="10" Value="MTBF"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352250" Local_ID="0" Value="48v, 1.25A" CategoryFeature_ID="808035" CategoryFeatureGroup_ID="1142" No="100200" Optional="0" Presentation_Value="48v, 1.25A" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="48v, 1.25A">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1390">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1335494" langid="10" Value="Fonte de energia"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352249" Local_ID="0" Value="59.3" CategoryFeature_ID="11195" CategoryFeatureGroup_ID="1142" No="100090" Optional="0" Presentation_Value="59,3 W" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="59,3">
    <Measure ID="44">
     <Signs>
      <Sign ID="45530" langid="10"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="445">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="45530" langid="10"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1334878" langid="10" Value="Consumo de energia (padrão)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352248" Local_ID="0" Value="Y" CategoryFeature_ID="17380" CategoryFeatureGroup_ID="9999" No="10100098" Optional="0" Presentation_Value="Sim" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Sim">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2988">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5935694" langid="10" Value="Power over Ethernet (PoE)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352225" Local_ID="0" Value="4 μs" CategoryFeature_ID="2032" CategoryFeatureGroup_ID="8343" No="100500" Optional="1" Presentation_Value="4 μs" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="4 μs">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="491">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1334915" langid="10" Value="Latência"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352245" Local_ID="0" Value="236 x 101.6 x 27" CategoryFeature_ID="5038" CategoryFeatureGroup_ID="8343" No="100050" Optional="1" Presentation_Value="236 x 101,6 x 27 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="236 x 101,6 x 27">
    <Measure ID="24">
     <Signs>
      <Sign ID="45515" langid="10"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="49">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="45515" langid="10"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1334832" langid="10" Value="Dimensões (L x P x A)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352228" Local_ID="0" Value="20" CategoryFeature_ID="8587" CategoryFeatureGroup_ID="8343" No="100001" Optional="1" Presentation_Value="20 Gbit/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="20">
    <Measure ID="68">
     <Signs>
      <Sign ID="45545" langid="10"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="2746">
    <Measure ID="68" Sign="">
     <Signs>
      <Sign ID="45545" langid="10"><![CDATA[Gbit/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1336509" langid="10" Value="Largura de banda"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="107505572" Local_ID="0" Value="Gigabit Ethernet" CategoryFeature_ID="14266" CategoryFeatureGroup_ID="8343" No="100000" Optional="1" Presentation_Value="Gigabit Ethernet" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Gigabit Ethernet">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1104">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1335333" langid="10" Value="Recursos de rede"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352256" Local_ID="0" Value="0 - 50" CategoryFeature_ID="7827" CategoryFeatureGroup_ID="1143" No="100040" Optional="0" Presentation_Value="0 - 50 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 50">
    <Measure ID="65">
     <Signs>
      <Sign ID="45543" langid="10"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1112">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="45543" langid="10"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1335339" langid="10" Value="Temperatura operação (T-T)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352257" Local_ID="0" Value="-20 - 70" CategoryFeature_ID="7830" CategoryFeatureGroup_ID="1143" No="100039" Optional="0" Presentation_Value="-20 - 70 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="-20 - 70">
    <Measure ID="65">
     <Signs>
      <Sign ID="45543" langid="10"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="757">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="45543" langid="10"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1335108" langid="10" Value="Temperatura de armazenamento (T-T)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352254" Local_ID="0" Value="10 - 90" CategoryFeature_ID="7825" CategoryFeatureGroup_ID="1143" No="100035" Optional="0" Presentation_Value="10 - 90%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10 - 90">
    <Measure ID="64">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="703">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1335064" langid="10" Value="Umidade relativa de operação (H-H)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352258" Local_ID="0" Value="10 - 95" CategoryFeature_ID="12190" CategoryFeatureGroup_ID="1143" No="100034" Optional="0" Presentation_Value="10 - 95%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10 - 95">
    <Measure ID="64">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1383">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="47" langid="1"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1335491" langid="10" Value="Umidade relativa de armazenamento (H-H)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352255" Local_ID="0" Value="0 - 3000" CategoryFeature_ID="7826" CategoryFeatureGroup_ID="1143" No="100020" Optional="0" Presentation_Value="0 - 3000 m" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 3000">
    <Measure ID="54">
     <Signs>
      <Sign ID="45537" langid="10"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="667">
    <Measure ID="54" Sign="">
     <Signs>
      <Sign ID="45537" langid="10"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1335037" langid="10" Value="Altitude de operação"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352259" Local_ID="0" Value="0 - 3000" CategoryFeature_ID="13094" CategoryFeatureGroup_ID="1143" No="100019" Optional="0" Presentation_Value="0 - 3000 m" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 3000">
    <Measure ID="54">
     <Signs>
      <Sign ID="45537" langid="10"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1449">
    <Measure ID="54" Sign="">
     <Signs>
      <Sign ID="45537" langid="10"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1335522" langid="10" Value="Altitude sem operação"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352246" Local_ID="0" Value="700" CategoryFeature_ID="8713" CategoryFeatureGroup_ID="1144" No="100000" Optional="0" Presentation_Value="700 g" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="700">
    <Measure ID="38">
     <Signs>
      <Sign ID="45525" langid="10"><![CDATA[g]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="94">
    <Measure ID="38" Sign="">
     <Signs>
      <Sign ID="45525" langid="10"><![CDATA[g]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1334861" langid="10" Value="Peso"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="106352253" Local_ID="0" Value="CE mark, FCC Part 15 Class A, VCCI Class A, C-Tick" CategoryFeature_ID="17378" CategoryFeatureGroup_ID="41469" No="99900" Optional="0" Presentation_Value="CE mark, FCC Part 15 Class A, VCCI Class A, C-Tick" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="CE mark, FCC Part 15 Class A, VCCI Class A, C-Tick">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="249">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1334865" langid="10" Value="Certificação"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/norm/low/8157604-251.jpg" LowPicHeight="127" LowPicWidth="200" LowSize="25916" No="1" Original="https://images.icecat.biz/img/norm/high/8157604-251.jpg" OriginalSize="196896" Pic="https://images.icecat.biz/img/norm/high/8157604-251.jpg" Pic500x500="https://images.icecat.biz/img/norm/medium/8157604-251.jpg" Pic500x500Height="318" Pic500x500Size="53322" Pic500x500Width="500" PicHeight="764" PicWidth="1200" ProductPicture_ID="14235662" Size="192165" ThumbPic="https://images.icecat.biz/thumbs/8157604.jpg" ThumbSize="2777" Type="ProductImage" UpdatedDate="2017-02-06 19:32:36"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2018-06-07 13:27:39" Description="Generated PDF" KeepAsURL="0" MultimediaObject_ID="0" Type="leaflet" UUID="00000000-0000-0000-0000-000000000000" langid="10" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="0" URL="https://icecat.biz/rest/product-pdf?productId=8157604&amp;lang=br" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated/>
  <SummaryDescription>
   <ShortSummaryDescription langid="10">NETGEAR GS110TP, Gerenciado, Transmissão full duplex, Power over Ethernet (PoE)</ShortSummaryDescription>
   <LongSummaryDescription langid="10">NETGEAR GS110TP. Tipo de switch: Gerenciado. Números de portas ethernet Basic switching RJ-45: 8. Transmissão full duplex. Tabela de endereços MAC: 4000 entradas. Padrões de rede: IEEE 802.3ab, IEEE 802.3af, IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z. Conector de poder: Tomada de entrada CC. Power over Ethernet (PoE)</LongSummaryDescription>
  </SummaryDescription>
  <Supplier ID="104" Name="NETGEAR"/>
  <CatalogObjectCloud>
   <ProductPage QRCodeURL="https://qr.icecat.biz/coc/69233499-df8d-491c-93e2-35e7cb2d8aa3" URL="https://coc.icecat.biz/69233499-df8d-491c-93e2-35e7cb2d8aa3"/>
  </CatalogObjectCloud>
 </Product>
</ICECAT-interface>
