<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ICECAT-interface SYSTEM "https://data.icecat.biz/dtd/ICECAT-interface_response.dtd">
<!--source: Icecat.biz 2026-->
<!--Language ID: 4-->
<!--Version: v2-->
<ICECAT-interface xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://data.icecat.biz/xsd/ICECAT-interface_response.xsd">
 <Product Code="1" HighPic="https://images.icecat.biz/img/gallery/25545980_0959.jpg" HighPicHeight="1000" HighPicSize="274987" HighPicWidth="651" ID="37909419" LowPic="https://images.icecat.biz/img/gallery_lows/25545980_0959.jpg" LowPicHeight="200" LowPicSize="13276" LowPicWidth="130" Name="TD350" IntName="TD350" LocalName="" Pic500x500="https://images.icecat.biz/img/gallery_mediums/25545980_0959.jpg" Pic500x500Height="500" Pic500x500Size="77589" Pic500x500Width="325" Prod_id="70DJ006MGE" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/25545980_0959.jpg" ThumbPicSize="1447" Title="Lenovo ThinkServer TD350 Server 0 GB Turm (4U) Intel® Xeon® E5 v4 E5-2620V4 2,1 GHz 8 GB DDR4-SDRAM 550 W" GeneratedIntTitle="Lenovo ThinkServer TD350 server" GeneratedLocalTitle="Lenovo ThinkServer TD350 Server 0 GB Turm (4U) Intel® Xeon® E5 v4 E5-2620V4 2,1 GHz 8 GB DDR4-SDRAM 550 W" BrandLocalTitle="">
  <CategoryFeatureGroup ID="10891" No="-80">
   <FeatureGroup ID="0">
    <Name ID="438000" langid="4" Value="Technische Details"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1051" No="100">
   <FeatureGroup ID="1">
    <Name ID="437973" langid="4" Value="Prozessor"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1049" No="90">
   <FeatureGroup ID="3">
    <Name ID="437975" langid="4" Value="Speicher"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2697" No="20">
   <FeatureGroup ID="5">
    <Name ID="437977" langid="4" Value="Bildschirm"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1053" No="50">
   <FeatureGroup ID="12">
    <Name ID="437983" langid="4" Value="Anschlüsse und Schnittstellen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1055" No="-5">
   <FeatureGroup ID="14">
    <Name ID="5789172" langid="4" Value="Gewicht und Abmessungen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1056" No="10">
   <FeatureGroup ID="27">
    <Name ID="5789178" langid="4" Value="Energie"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2698" No="5">
   <FeatureGroup ID="28">
    <Name ID="437998" langid="4" Value="Betriebsbedingungen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1054" No="60">
   <FeatureGroup ID="35">
    <Name ID="438005" langid="4" Value="Netzwerk"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8609" No="80">
   <FeatureGroup ID="47">
    <Name ID="5789131" langid="4" Value="Speichermedium"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="23800" No="-10">
   <FeatureGroup ID="67">
    <Name ID="5789156" langid="4" Value="Verpackungsdaten"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2695" No="3">
   <FeatureGroup ID="76">
    <Name ID="438043" langid="4" Value="Zertifikate"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="11644" No="15">
   <FeatureGroup ID="90">
    <Name ID="438055" langid="4" Value="Software"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="7714" No="-20">
   <FeatureGroup ID="116">
    <Name ID="4480855" langid="4" Value="Lieferumfang"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="4192" No="40">
   <FeatureGroup ID="124">
    <Name ID="438087" langid="4" Value="Erweiterungssteckplätze"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53421" No="0">
   <FeatureGroup ID="143">
    <Name ID="1030928" langid="4" Value="Akku/Batterie"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8611" No="-100">
   <FeatureGroup ID="146">
    <Name ID="5789159" langid="4" Value="Sonstige Funktionen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10890" No="30">
   <FeatureGroup ID="148">
    <Name ID="630460" langid="4" Value="Design"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8610" No="70">
   <FeatureGroup ID="163">
    <Name ID="764416" langid="4" Value="Grafik"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="12136" No="13">
   <FeatureGroup ID="183">
    <Name ID="1210974" langid="4" Value="Prozessor Besonderheiten"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10889" No="25">
   <FeatureGroup ID="184">
    <Name ID="1218768" langid="4" Value="Leistungen"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="20049" No="-70">
   <FeatureGroup ID="185">
    <Name ID="5789155" langid="4" Value="Merkmale"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="35829" No="0">
   <FeatureGroup ID="198">
    <Name ID="5789137" langid="4" Value="Logistikdaten"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="59907" No="0">
   <FeatureGroup ID="232">
    <Name ID="3584770" langid="4" Value="Lieferanteneigenschaften"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="76092" No="0">
   <FeatureGroup ID="279">
    <Name ID="7392241" langid="4" Value="Nachhaltigkeit"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="77982" No="0">
   <FeatureGroup ID="305">
    <Name ID="8858201" langid="4" Value="CO2-Fußabdruck"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="156">
   <Name ID="436938" langid="4" Value="Server"/>
  </Category>
  <EANCode/>
  <FeatureLogo ID="91" Feature_ID="22268" Value="Y" LogoPic="https://images.icecat.biz/img/feature_logo/91-5976.png" Width="200" Height="200" Size="0">
   <Descriptions>
    <Description ID="2616" langid="1">Does not contain &quot;conflict minerals&quot;: tantalum, tin, tungsten, and gold.</Description>
   </Descriptions>
   <FeatureLogoFeatures>
    <FeatureLogoFeature ID="22268">
     <FeatureLogoValues>
      <FeatureLogoValue ID="197">Y</FeatureLogoValue>
     </FeatureLogoValues>
    </FeatureLogoFeature>
   </FeatureLogoFeatures>
  </FeatureLogo>
  <FeatureLogo ID="1498" Feature_ID="2196" Value="Intel Xeon E5 v4" LogoPic="https://images.icecat.biz/img/feature_logo/1498-1295.png" Width="0" Height="0" Size="0">
   <Descriptions>
    <Description ID="6181" langid="4">Intel® Xeon® Prozessoren bieten Cloud Computing, Echtzeitanalysen, Verarbeitung für Ihr geschäftskritisches Unternehmen und Big Data-Einblicke. Verbessern Sie die Effizienz und Zuverlässigkeit Ihres Rechenzentrums, um jede Arbeitslast zu bewältigen.</Description>
   </Descriptions>
   <FeatureLogoFeatures>
    <FeatureLogoFeature ID="2196">
     <FeatureLogoValues>
      <FeatureLogoValue ID="6619">Intel Xeon E5 v4</FeatureLogoValue>
     </FeatureLogoValues>
    </FeatureLogoFeature>
   </FeatureLogoFeatures>
  </FeatureLogo>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy/>
  <BulletPoints/>
  <GeneratedBulletPoints>
   <GeneratedBulletPoint Value="Intel® Xeon® E5 v4 E5-2620V4 2,1 GHz" langid="4" No="1"/>
   <GeneratedBulletPoint Value="8 GB 2400 MHz DDR4-SDRAM 1 x 8" langid="4" No="2"/>
   <GeneratedBulletPoint Value="DVD±RW" langid="4" No="3"/>
   <GeneratedBulletPoint Value="Turm (4U) 550 W" langid="4" No="4"/>
  </GeneratedBulletPoints>
  <ProductBundled/>
  <ProductDescription ID="62132864" LongDesc="&lt;b&gt;Optimal dimensionierte Rechenleistung für perfekte Performance&lt;/b&gt;&lt;br&gt;Mit dem ThinkServer TD350 können Sie hohe Leistung und massive Speicherkapazität in Einklang bringen, ohne in eine Rack-Infrastruktur investieren zu müssen. Der Tower der nächsten Generation bietet eine fast dreimal so hohe Speicherkapazität wie der TD340, bis zu 512 GB DDR4 und eine Verdoppelung der Speicherkapazität auf bis zu 90 TB. Durch sein innovatives Design stellt der 4U-Tower-Server im Vergleich zu Mitbewerbern 25 Prozent mehr Festplatten pro 1U und dabei schnellere Dateiübertragungen und höhere IOPs-Leistung bereit. Als interne Option zum sicheren Hochfahren sind zwei zusätzliche M.2-Solid-State-Laufwerke der Enterprise-Klasse verfügbar. All diese Merkmale bedeuten letztlich Mehrwert für Ihr Unternehmen!&lt;br&gt;&lt;br&gt;&lt;b&gt;Für jede Umgebung geeignet&lt;/b&gt;&lt;br&gt;Mit Remote-Zugriff und offenen Industriestandards ist der ThinkServer TD350 ein idealer Tower-Server für jede Umgebung – egal, ob im Tower-Format für das Front-Office oder rackmontiert zum Einsatz in wachsenden Rechenzentren. Nutzen Sie Ihre vorhandenen Verwaltungstools oder probieren Sie unsere – ohne zusätzliche Kosten! Das Design ist ENERGY STAR-konform, bietet hocheffiziente Netzteiloptionen für niedrigere Betriebskosten und ermöglicht einen Dauerbetrieb bei 45 Grad Celsius – ohne Zeiteinschränkungen und ohne Auswirkungen auf die Zuverlässigkeit. Der TD350 ist einfach einzurichten und bietet mit nur 37 Dezibel einen extrem leisen Betrieb. Kurz: Er liefert die Leistung eines Enterprise-Rack-Servers im kompakten Gehäuse eines Towers.&lt;br&gt;&lt;br&gt;&lt;b&gt;Wächst mit dem Unternehmen mit&lt;/b&gt;&lt;br&gt;Dank flexibler Konfigurationsmöglichkeiten ist der TD350 höchst anpassungsfähig. Durch seine interne Erweiterbarkeit wächst er mit den geschäftlichen Anforderungen mit. So erhalten Sie einen exzellenten Investitionsschutz mit niedrigeren Gesamtbetriebskosten und besserer Investitionsrendite. 95 Prozent der von Kunden austauschbaren Komponenten sind ohne Werkzeug zugänglich – dies vereinfacht die Installation und Erweiterung enorm. So können Sie Ihr System im Handumdrehen von fünf nicht Hot-Swap-fähigen SATA-Laufwerken und zwei integrierten NIC-Anschlüssen auf 32 Hot-Swap-Laufwerke, Hardware-RAID und mehrere 10-Gbit/s-NIC-Anschlüsse erweitern. Kleinunternehmen können in einen TD350 investieren, um ihn zunächst als Datei-/Druckserver mit entsprechendem Hosting zu nutzen, und ihn dann ganz einfach skalieren, damit komplexere Geschäftsanalysen und große Datenbanken unterstützt werden." ManualPDFSize="0" ManualPDFURL="" MiddleDesc="" PDFSize="0" PDFURL="" ShortDesc="2 x Intel Xeon E5-2620 v4 (20M Cache, 2.1GHz), 8GB DDR4 2400MHz, 8x2.5&quot; HS, AnyRAID 720ix + 2GB Flash, DVD±RW, 550Wx1 Platinum, 4U Tower" URL="http://shop.lenovo.com/de/de/systems/servers/towers/td350/#tab-features" WarrantyInfo="3 Jahre" langid="4"/>
  <ProductFamily ID="968" LowPic="" ThumbPic="">
   <Name ID="224058" langid="1" Value="ThinkServer"/>
   <Series ID="867">
    <Name ID="799210" langid="1" Value="TD"/>
   </Series>
  </ProductFamily>
  <ProductFeature Localized="0" ID="271852821" Local_ID="0" Value="Intel Xeon E5 v4" CategoryFeature_ID="11563" CategoryFeatureGroup_ID="1051" No="10100400" Optional="0" Presentation_Value="Intel® Xeon® E5 v4" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Intel® Xeon® E5 v4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2196">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449349" langid="4" Value="Prozessorfamilie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="379037792" Local_ID="0" Value="Intel" CategoryFeature_ID="4443" CategoryFeatureGroup_ID="1051" No="10213006" Optional="0" Presentation_Value="Intel" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="Intel">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1013">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449208" langid="4" Value="Prozessorhersteller"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852813" Local_ID="0" Value="E5-2620V4" CategoryFeature_ID="1239" CategoryFeatureGroup_ID="1051" No="100398" Optional="0" Presentation_Value="E5-2620V4" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="E5-2620V4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="47">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449040" langid="4" Value="Prozessor"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852803" Local_ID="0" Value="2.1" CategoryFeature_ID="73717" CategoryFeatureGroup_ID="1051" No="100396" Optional="0" Presentation_Value="2,1 GHz" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="2,1">
    <Measure ID="37">
     <Signs>
      <Sign ID="13070" langid="4"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11379">
    <Measure ID="37" Sign="">
     <Signs>
      <Sign ID="13070" langid="4"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1036527" langid="4" Value="Prozessor-Taktfrequenz"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852952" Local_ID="0" Value="3" CategoryFeature_ID="72626" CategoryFeatureGroup_ID="1051" No="100395" Optional="0" Presentation_Value="3 GHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3">
    <Measure ID="37">
     <Signs>
      <Sign ID="13070" langid="4"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="7978">
    <Measure ID="37" Sign="">
     <Signs>
      <Sign ID="13070" langid="4"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="617141" langid="4" Value="Prozessor Boost-Frequenz"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852826" Local_ID="0" Value="8" CategoryFeature_ID="31274" CategoryFeatureGroup_ID="1051" No="100300" Optional="0" Presentation_Value="8" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6089">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445205" langid="4" Value="Anzahl Prozessorkerne"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852846" Local_ID="0" Value="20" CategoryFeature_ID="135262" CategoryFeatureGroup_ID="1051" No="100290" Optional="0" Presentation_Value="20 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="20">
    <Measure ID="19">
     <Signs>
      <Sign ID="6667" langid="4"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="10041">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="6667" langid="4"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1323603" langid="4" Value="Prozessor-Cache"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852929" Local_ID="0" Value="Intel C610" CategoryFeature_ID="47167" CategoryFeatureGroup_ID="1051" No="100250" Optional="0" Presentation_Value="Intel C610" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Intel C610">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="436">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445673" langid="4" Value="Motherboard Chipsatz"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871836" Local_ID="0" Value="Quad" CategoryFeature_ID="135002" CategoryFeatureGroup_ID="1051" No="100240" Optional="1" Presentation_Value="Quad" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Quad">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21997">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1830205" langid="4" Value="Speicherkanäle, vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852829" Local_ID="0" Value="2" CategoryFeature_ID="1280" CategoryFeatureGroup_ID="1051" No="100090" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="596">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445687" langid="4" Value="Anzahl installierter Prozessoren"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871849" Local_ID="0" Value="85" CategoryFeature_ID="135036" CategoryFeatureGroup_ID="1051" No="100010" Optional="1" Presentation_Value="85 W" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="85">
    <Measure ID="44">
     <Signs>
      <Sign ID="13076" langid="4"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11778">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="13076" langid="4"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1090647" langid="4" Value="Thermal Design Power (TDP)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852840" Local_ID="0" Value="Smart Cache" CategoryFeature_ID="135210" CategoryFeatureGroup_ID="1051" No="100005" Optional="1" Presentation_Value="Smart Cache" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Smart Cache">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21716">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1766293" langid="4" Value="Prozessor Cache Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852875" Local_ID="0" Value="8" CategoryFeature_ID="39190" CategoryFeatureGroup_ID="1051" No="100002" Optional="1" Presentation_Value="8 GT/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8">
    <Measure ID="176">
     <Signs>
      <Sign ID="13138" langid="4"><![CDATA[GT/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="6975">
    <Measure ID="176" Sign="">
     <Signs>
      <Sign ID="13138" langid="4"><![CDATA[GT/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449529" langid="4" Value="Systembus-Rate"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852903" Local_ID="0" Value="LGA 2011-v3" CategoryFeature_ID="39841" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="LGA 2011-v3" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="LGA 2011-v3">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2325">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449438" langid="4" Value="Prozessorsockel"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871814" Local_ID="0" Value="14" CategoryFeature_ID="134949" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="14 nm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="14">
    <Measure ID="98">
     <Signs>
      <Sign ID="13100" langid="4"><![CDATA[nm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1623">
    <Measure ID="98" Sign="">
     <Signs>
      <Sign ID="13100" langid="4"><![CDATA[nm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449839" langid="4" Value="Prozessor Lithografie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852961" Local_ID="0" Value="16" CategoryFeature_ID="134950" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="16" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="16">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7337">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1027770" langid="4" Value="Prozessor-Threads"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871815" Local_ID="0" Value="64-bit" CategoryFeature_ID="134951" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="64-Bit" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="64-Bit">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7975">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323409" langid="4" Value="Prozessorbetriebsmodi"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871816" Local_ID="0" Value="R0" CategoryFeature_ID="134952" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="R0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="R0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3254">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323108" langid="4" Value="Stepping"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871817" Local_ID="0" Value="QPI" CategoryFeature_ID="134954" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="QPI" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="QPI">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10286">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030093" langid="4" Value="Bus Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871818" Local_ID="0" Value="2" CategoryFeature_ID="134955" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10328">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030112" langid="4" Value="Anzahl der QPI links"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871819" Local_ID="0" Value="Broadwell" CategoryFeature_ID="134956" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Broadwell" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Broadwell">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="18767">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1436337" langid="4" Value="Prozessor Codename"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871820" Local_ID="0" Value="74" CategoryFeature_ID="134958" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="74 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="74">
    <Measure ID="65">
     <Signs>
      <Sign ID="13083" langid="4"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="10278">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="13083" langid="4"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="884654" langid="4" Value="Tcase"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871832" Local_ID="0" Value="1536" CategoryFeature_ID="134998" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="1,53 TB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1,53">
    <Measure ID="159">
     <Signs>
      <Sign ID="13128" langid="4"><![CDATA[TB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21987">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1830202" langid="4" Value="Maximaler interner Speicher, vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871833" Local_ID="0" Value="DDR4-SDRAM" CategoryFeature_ID="134999" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="DDR4-SDRAM" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="DDR4-SDRAM">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21994">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1830203" langid="4" Value="Speichertypen, vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871834" Local_ID="0" Value="1600,1866,2133" CategoryFeature_ID="135000" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="1600,1866,2133 MHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1600,1866,2133">
    <Measure ID="18">
     <Signs>
      <Sign ID="13057" langid="4"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21995">
    <Measure ID="18" Sign="">
     <Signs>
      <Sign ID="13057" langid="4"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1830204" langid="4" Value="Speichertaktraten, vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871835" Local_ID="0" Value="68.3" CategoryFeature_ID="135001" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="68,3 GB/s" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="68,3">
    <Measure ID="160">
     <Signs>
      <Sign ID="19041" langid="4"><![CDATA[GB/s]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21996">
    <Measure ID="160" Sign="">
     <Signs>
      <Sign ID="19041" langid="4"><![CDATA[GB/s]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1748594" langid="4" Value="Durch den Prozessor (max) unterstützte Speicherbandbreite"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871837" Local_ID="0" Value="Y" CategoryFeature_ID="135003" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21998">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1830206" langid="4" Value="ECC vom Prozessor unterstützt"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871838" Local_ID="0" Value="Y" CategoryFeature_ID="135019" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10196">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="880000" langid="4" Value="Execute Disable Bit"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871839" Local_ID="0" Value="Y" CategoryFeature_ID="135021" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10197">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030033" langid="4" Value="Leerlauf Zustände"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871840" Local_ID="0" Value="Y" CategoryFeature_ID="135022" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10199">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030034" langid="4" Value="Thermal-Überwachungstechnologien"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871841" Local_ID="0" Value="40" CategoryFeature_ID="135023" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="40" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="40">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="20905">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1694259" langid="4" Value="Maximale Anzahl der PCI-Express-Lanes"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871842" Local_ID="0" Value="45 x 52.5" CategoryFeature_ID="135025" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="45 x 52.5 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="45 x 52.5">
    <Measure ID="24">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="22011">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1830214" langid="4" Value="Prozessor-Paketgröße"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871843" Local_ID="0" Value="AVX 2.0" CategoryFeature_ID="135026" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="AVX 2.0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="AVX 2.0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3260">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323110" langid="4" Value="Unterstützte Befehlssätze"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871844" Local_ID="0" Value="SR2R6" CategoryFeature_ID="135027" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="SR2R6" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="SR2R6">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="6090">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449847" langid="4" Value="Prozessor-Code"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871845" Local_ID="0" Value="2S" CategoryFeature_ID="135028" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="2S" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2S">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10265">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030084" langid="4" Value="Skalierbarkeit"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871846" Local_ID="0" Value="Y" CategoryFeature_ID="135029" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10273">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="884444" langid="4" Value="Physical Address Extension (PAE)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871847" Local_ID="0" Value="46" CategoryFeature_ID="135030" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="46 Bit" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="46">
    <Measure ID="50">
     <Signs>
      <Sign ID="6674" langid="4"><![CDATA[Bit]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="21778">
    <Measure ID="50" Sign="">
     <Signs>
      <Sign ID="6674" langid="4"><![CDATA[Bit]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1830093" langid="4" Value="Physical Address Extension (PAE)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871848" Local_ID="0" Value="Y" CategoryFeature_ID="135032" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10283">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030091" langid="4" Value="Eingebettete Optionen verfügbar"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="275069176" Local_ID="0" Value="Intel Xeon E5-2600 v4" CategoryFeature_ID="140317" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Intel Xeon E5-2600 v4" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Intel Xeon E5-2600 v4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21719">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1830050" langid="4" Value="Prozessor-Serien"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871852" Local_ID="0" Value="Y" CategoryFeature_ID="135137" CategoryFeatureGroup_ID="1051" No="99990" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="22268">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1830346" langid="4" Value="Konfliktloser-Prozessor"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852966" Local_ID="0" Value="8" CategoryFeature_ID="73754" CategoryFeatureGroup_ID="1049" No="10100200" Optional="0" Presentation_Value="8 GB" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="8">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11381">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1036619" langid="4" Value="Speicherkapazität"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852971" Local_ID="0" Value="DDR4-SDRAM" CategoryFeature_ID="4437" CategoryFeatureGroup_ID="1049" No="10100198" Optional="0" Presentation_Value="DDR4-SDRAM" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="DDR4-SDRAM">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="427">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449067" langid="4" Value="Interner Speichertyp"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852973" Local_ID="0" Value="512" CategoryFeature_ID="4705" CategoryFeatureGroup_ID="1049" No="99990" Optional="0" Presentation_Value="512 GB" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="512">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1452">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449246" langid="4" Value="RAM-Speicher maximal"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852987" Local_ID="0" Value="16" CategoryFeature_ID="5722" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="16" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="16">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="672">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449103" langid="4" Value="Speicherkartensteckplätze"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852976" Local_ID="0" Value="Y" CategoryFeature_ID="20420" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1628">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445845" langid="4" Value="ECC"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852994" Local_ID="0" Value="2400" CategoryFeature_ID="31277" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="2400 MHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2400">
    <Measure ID="18">
     <Signs>
      <Sign ID="13057" langid="4"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="2900">
    <Measure ID="18" Sign="">
     <Signs>
      <Sign ID="13057" langid="4"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449448" langid="4" Value="Speichertaktfrequenz"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852980" Local_ID="0" Value="1 x 8" CategoryFeature_ID="73739" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="1 x 8 GB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1 x 8">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11380">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1036575" langid="4" Value="Speicherlayout"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271852999" Local_ID="0" Value="0" CategoryFeature_ID="18867" CategoryFeatureGroup_ID="8609" No="213001" Optional="0" Presentation_Value="0 GB" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="0">
    <Measure ID="20">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="3318">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6668" langid="4"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449474" langid="4" Value="Gesamtspeicherkapazität"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853019" Local_ID="0" Value="Y" CategoryFeature_ID="41696" CategoryFeatureGroup_ID="8609" No="100820" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7335">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323345" langid="4" Value="RAID-Unterstützung"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853200" Local_ID="0" Value="DVD±RW" CategoryFeature_ID="5723" CategoryFeatureGroup_ID="8609" No="100000" Optional="0" Presentation_Value="DVD±RW" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="DVD±RW">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1120">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449288" langid="4" Value="Optisches Laufwerk - Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853004" Local_ID="0" Value="0" CategoryFeature_ID="18868" CategoryFeatureGroup_ID="8609" No="100951" Optional="0" Presentation_Value="0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3319">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5148649" langid="4" Value="Anzahl der installierten HDDs"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853014" Local_ID="0" Value="Serial ATA III,Serial Attached SCSI (SAS)" CategoryFeature_ID="4431" CategoryFeatureGroup_ID="8609" No="100940" Optional="0" Presentation_Value="Serial ATA III, Serial Attached SCSI (SAS)" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Serial ATA III, Serial Attached SCSI (SAS)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="982">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5148645" langid="4" Value="HDD Schnittstelle"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853007" Local_ID="0" Value="2.5" CategoryFeature_ID="20726" CategoryFeatureGroup_ID="8609" No="100929" Optional="0" Presentation_Value="2.5&quot;" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.5">
    <Measure ID="16">
     <Signs>
      <Sign ID="22180" langid="4"><![CDATA["]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1926">
    <Measure ID="16" Sign="">
     <Signs>
      <Sign ID="22180" langid="4"><![CDATA["]]></Sign>
     </Signs>
    </Measure>
    <Name ID="5148647" langid="4" Value="HDD Größe"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853101" Local_ID="0" Value="8" CategoryFeature_ID="28496" CategoryFeatureGroup_ID="8609" No="100925" Optional="0" Presentation_Value="8" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3392">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="5148650" langid="4" Value="Maximale unterstützte Anzahl der HDD"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853118" Local_ID="0" Value="2.5" CategoryFeature_ID="66074" CategoryFeatureGroup_ID="8609" No="100924" Optional="0" Presentation_Value="2.5&quot;" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.5">
    <Measure ID="16">
     <Signs>
      <Sign ID="22180" langid="4"><![CDATA["]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="7140">
    <Measure ID="16" Sign="">
     <Signs>
      <Sign ID="22180" langid="4"><![CDATA["]]></Sign>
     </Signs>
    </Measure>
    <Name ID="1027705" langid="4" Value="Unterstützte Hard-Disk Drive Größen"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853039" Local_ID="0" Value="0,1,5,10,50" CategoryFeature_ID="4659" CategoryFeatureGroup_ID="8609" No="100810" Optional="0" Presentation_Value="0, 1, 5, 10, 50" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0, 1, 5, 10, 50">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1470">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445166" langid="4" Value="RAID Level"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853073" Local_ID="0" Value="720i" CategoryFeature_ID="166992" CategoryFeatureGroup_ID="8609" No="100800" Optional="0" Presentation_Value="720i" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="720i">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="26528">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2342400" langid="4" Value="Unterstützte RAID-Controller"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853125" Local_ID="0" Value="Y" CategoryFeature_ID="93897" CategoryFeatureGroup_ID="8609" No="100690" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="5576">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323253" langid="4" Value="Hot-Swap"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853136" Local_ID="0" Value="SAS,Serial ATA III" CategoryFeature_ID="192047" CategoryFeatureGroup_ID="8609" No="100000" Optional="1" Presentation_Value="SAS, Serial ATA III" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="SAS, Serial ATA III">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="19205">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1513670" langid="4" Value="Unterstützte Speicherlaufwerk-Schnittstellen"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853151" Local_ID="0" Value="Y" CategoryFeature_ID="64539" CategoryFeatureGroup_ID="8610" No="100200" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9997">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1029886" langid="4" Value="Eingebaute Grafikadapter"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853167" Local_ID="0" Value="Aspeed AST2400" CategoryFeature_ID="134996" CategoryFeatureGroup_ID="8610" No="100195" Optional="0" Presentation_Value="Aspeed AST2400" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Aspeed AST2400">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9016">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="757355" langid="4" Value="Eingebautes Grafikkartenmodell"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853149" Local_ID="0" Value="16" CategoryFeature_ID="1275" CategoryFeatureGroup_ID="8610" No="99990" Optional="0" Presentation_Value="16 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="16">
    <Measure ID="19">
     <Signs>
      <Sign ID="6667" langid="4"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="574">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="6667" langid="4"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449086" langid="4" Value="Maximaler Grafikkartenspeicher"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853174" Local_ID="0" Value="Y" CategoryFeature_ID="41697" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1347">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="445794" langid="4" Value="Ethernet/LAN"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853172" Local_ID="0" Value="10/100/1000Base-T(X)" CategoryFeature_ID="56945" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="10/100/1000Base-T(X)" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10/100/1000Base-T(X)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="747">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449112" langid="4" Value="Verkabelungstechnologie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853173" Local_ID="0" Value="Gigabit Ethernet" CategoryFeature_ID="58780" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="Gigabit Ethernet" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Gigabit Ethernet">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7484">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1027885" langid="4" Value="Ethernet Schnittstellen Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853183" Local_ID="0" Value="2" CategoryFeature_ID="16225" CategoryFeatureGroup_ID="1053" No="101000" Optional="0" Presentation_Value="2" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2312">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449325" langid="4" Value="Anzahl Ethernet-LAN-Anschlüsse (RJ-45)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853176" Local_ID="0" Value="2" CategoryFeature_ID="17114" CategoryFeatureGroup_ID="1053" No="100500" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2308">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449424" langid="4" Value="Anzahl USB 2.0 Anschlüsse"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853177" Local_ID="0" Value="4" CategoryFeature_ID="138415" CategoryFeatureGroup_ID="1053" No="100490" Optional="0" Presentation_Value="4" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="4">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="22701">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1791611" langid="4" Value="USB 3.2 Gen 1 (3.1 Gen 1) Anzahl der Anschlüsse vom Typ A"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853182" Local_ID="0" Value="1" CategoryFeature_ID="16223" CategoryFeatureGroup_ID="1053" No="100000" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2323">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449437" langid="4" Value="Anzahl VGA (D-Sub) Anschlüsse"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853184" Local_ID="0" Value="1" CategoryFeature_ID="17113" CategoryFeatureGroup_ID="1053" No="100000" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1337">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449335" langid="4" Value="Anzahl serielle Anschlüsse"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853187" Local_ID="0" Value="5" CategoryFeature_ID="85518" CategoryFeatureGroup_ID="4192" No="100077" Optional="0" Presentation_Value="5" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="5">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="13456">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323670" langid="4" Value="PCI-Express x8 (Gen 3.x)-Anschlüsse"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853190" Local_ID="0" Value="2" CategoryFeature_ID="92208" CategoryFeatureGroup_ID="4192" No="100067" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="15790">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323682" langid="4" Value="PCI-Express x16 (Gen 3.x)-Anschlüsse"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871809" Local_ID="0" Value="3.0" CategoryFeature_ID="46575" CategoryFeatureGroup_ID="4192" No="100000" Optional="1" Presentation_Value="3.0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3.0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7825">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1323388" langid="4" Value="PCI-Express-Slots-Version"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853197" Local_ID="0" Value="Tower (4U)" CategoryFeature_ID="1235" CategoryFeatureGroup_ID="10890" No="10113007" Optional="0" Presentation_Value="Turm (4U)" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Turm (4U)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="734">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449109" langid="4" Value="Gehäusetyp"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853230" Local_ID="0" Value="UEFI" CategoryFeature_ID="62967" CategoryFeatureGroup_ID="10889" No="100000" Optional="0" Presentation_Value="UEFI" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="UEFI">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1829">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="448305" langid="4" Value="BIOS-Typ"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853203" Local_ID="0" Value="N" CategoryFeature_ID="20423" CategoryFeatureGroup_ID="11644" No="100090" Optional="0" Presentation_Value="Nein" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3233">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449472" langid="4" Value="Installiertes Betriebssystem"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853218" Local_ID="0" Value="Microsoft Windows Server 2012 R2, 2012, 2008 R2&#10;Windows Small Business Server 2011&#10;Red Hat Enterprise Linux 6.5&#10;SUSE Linux Enterprise Server 11&#10;VMware vSphere (ESXi) 5.5 U2" CategoryFeature_ID="1289" CategoryFeatureGroup_ID="11644" No="100085" Optional="0" Presentation_Value="Microsoft Windows Server 2012 R2, 2012, 2008 R2&#10;Windows Small Business Server 2011&#10;Red Hat Enterprise Linux 6.5&#10;SUSE Linux Enterprise Server 11&#10;VMware vSphere (ESXi) 5.5 U2" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="Microsoft Windows Server 2012 R2, 2012, 2008 R2&#10;Windows Small Business Server 2011&#10;Red Hat Enterprise Linux 6.5&#10;SUSE Linux Enterprise Server 11&#10;VMware vSphere (ESXi) 5.5 U2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2507">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="449442" langid="4" Value="Kompatible Betriebssysteme"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871810" Local_ID="0" Value="2" CategoryFeature_ID="70253" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10275">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030088" langid="4" Value="CPU Konfiguration (max)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871811" Local_ID="0" Value="Y" CategoryFeature_ID="105685" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10195">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030032" langid="4" Value="Verbesserte Intel SpeedStep Technologie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871812" Local_ID="0" Value="N" CategoryFeature_ID="105686" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9665">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234202" langid="4" Value="Intel® Identity-Protection-Technologie (Intel® IPT)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871813" Local_ID="0" Value="Y" CategoryFeature_ID="131546" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="18653">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234190" langid="4" Value="Intel® Virtualisierungstechnik für direkte I/O (VT-d)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871821" Local_ID="0" Value="Y" CategoryFeature_ID="134961" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9672">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234201" langid="4" Value="Intel® Hyper-Threading-Technik (Intel® HT Technology)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871822" Local_ID="0" Value="2.0" CategoryFeature_ID="134965" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="2.0" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2.0">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9733">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234183" langid="4" Value="Intel® Turbo-Boost-Technologie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871823" Local_ID="0" Value="N" CategoryFeature_ID="134971" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Nein" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nein">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10189">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234127" langid="4" Value="Intel® Flex Memory Access"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871824" Local_ID="0" Value="Y" CategoryFeature_ID="134975" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10194">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234197" langid="4" Value="Intel® AES New Instructions (Intel® AES-NI)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871825" Local_ID="0" Value="Y" CategoryFeature_ID="134979" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10200">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234179" langid="4" Value="Intel® Trusted-Execution-Technik"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871826" Local_ID="0" Value="Y" CategoryFeature_ID="134980" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10276">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234121" langid="4" Value="Intel® Enhanced Halt State"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871827" Local_ID="0" Value="Y" CategoryFeature_ID="134981" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10282">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234192" langid="4" Value="Intel® VT-x mit Extended Page Tables (EPT)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871828" Local_ID="0" Value="Y" CategoryFeature_ID="134982" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10285">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234118" langid="4" Value="Intel® Demand Based Switching"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871829" Local_ID="0" Value="Y" CategoryFeature_ID="134983" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="14804">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234208" langid="4" Value="Intel® Sicherer Schlüssel"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871830" Local_ID="0" Value="Y" CategoryFeature_ID="134984" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="14803">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234180" langid="4" Value="Intel® TSX-NI"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871831" Local_ID="0" Value="Y" CategoryFeature_ID="134986" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="17742">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234206" langid="4" Value="Intel® OS Guard"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871850" Local_ID="0" Value="Y" CategoryFeature_ID="135037" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="15741">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234103" langid="4" Value="Intel® 64"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="380048917" Local_ID="0" Value="0.00" CategoryFeature_ID="135103" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="0,00" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0,00">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21709">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234134" langid="4" Value="Intel® Identity Protection Technologieversion"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="380188683" Local_ID="0" Value="1.00" CategoryFeature_ID="135109" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="1,00" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1,00">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21711">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234164" langid="4" Value="Intel® Secure Key Technologieversion"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871851" Local_ID="0" Value="Y" CategoryFeature_ID="135110" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21759">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234188" langid="4" Value="Intel® Virtualization Technologie (VT-X)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="380632756" Local_ID="0" Value="1.00" CategoryFeature_ID="135126" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="1,00" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1,00">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21835">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2234181" langid="4" Value="Intel® TSX-NI-Version"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271871853" Local_ID="0" Value="92986" CategoryFeature_ID="176718" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="92986" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="92986">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="27646">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="2479344" langid="4" Value="ARK Prozessorerkennung"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853237" Local_ID="0" Value="Y" CategoryFeature_ID="26567" CategoryFeatureGroup_ID="1056" No="10100200" Optional="0" Presentation_Value="Ja" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3247">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="447888" langid="4" Value="Unterstützung für redundantes Netzteil"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853241" Local_ID="0" Value="550" CategoryFeature_ID="4718" CategoryFeatureGroup_ID="1056" No="100095" Optional="0" Presentation_Value="550 W" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="550">
    <Measure ID="44">
     <Signs>
      <Sign ID="13076" langid="4"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1242">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="13076" langid="4"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449318" langid="4" Value="Stromversorgung"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853246" Local_ID="0" Value="2" CategoryFeature_ID="77773" CategoryFeatureGroup_ID="1056" No="100090" Optional="0" Presentation_Value="2" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="11576">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1090494" langid="4" Value="Anzahl der unterstützten redundanten Stromversorgungen"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853248" Local_ID="0" Value="1" CategoryFeature_ID="77771" CategoryFeatureGroup_ID="1056" No="100088" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="11577">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1090495" langid="4" Value="Anzahl der installierten redundanten Netzteile"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853260" Local_ID="0" Value="251" CategoryFeature_ID="6245" CategoryFeatureGroup_ID="1055" No="100040" Optional="0" Presentation_Value="251 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="251">
    <Measure ID="24">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1649">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449371" langid="4" Value="Breite"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853265" Local_ID="0" Value="686" CategoryFeature_ID="6241" CategoryFeatureGroup_ID="1055" No="100000" Optional="0" Presentation_Value="686 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="686">
    <Measure ID="24">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1650">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449372" langid="4" Value="Tiefe"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853267" Local_ID="0" Value="459" CategoryFeature_ID="6244" CategoryFeatureGroup_ID="1055" No="100000" Optional="0" Presentation_Value="459 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="459">
    <Measure ID="24">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1464">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="13060" langid="4"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="449354" langid="4" Value="Höhe"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="271853234" Local_ID="0" Value="Y" CategoryFeature_ID="70254" CategoryFeatureGroup_ID="8611" No="100000" Optional="1" Presentation_Value="Ja" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Ja">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10365">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="1030138" langid="4" Value="Integrierter BMC mit IPMI"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/gallery_lows/25545980_0959.jpg" LowPicHeight="200" LowPicWidth="130" LowSize="13276" No="1" Original="https://images.icecat.biz/img/gallery_raw/25545980_0959.jpeg" OriginalSize="316276" Pic="https://images.icecat.biz/img/gallery/25545980_0959.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/25545980_0959.jpg" Pic500x500Height="500" Pic500x500Size="77589" Pic500x500Width="325" PicHeight="1000" PicWidth="651" ProductPicture_ID="25175288" Size="274987" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/25545980_0959.jpg" ThumbSize="1447" Type="ProductImage" UpdatedDate="2022-12-20 19:04:21"/>
   <ProductPicture LowPic="https://images.icecat.biz/img/gallery_lows/31815437_6755.jpg" LowPicHeight="200" LowPicWidth="117" LowSize="12729" No="2" Original="https://images.icecat.biz/img/gallery_raw/31815437_6755.jpeg" OriginalSize="291883" Pic="https://images.icecat.biz/img/gallery/31815437_6755.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/31815437_6755.jpg" Pic500x500Height="500" Pic500x500Size="75331" Pic500x500Width="292" PicHeight="1000" PicWidth="585" ProductPicture_ID="25175289" Size="256860" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/31815437_6755.jpg" ThumbSize="1374" Type="ProductImage" UpdatedDate="2024-03-08 09:07:54"/>
   <ProductPicture LowPic="https://images.icecat.biz/img/gallery_lows/31815437_6955.jpg" LowPicHeight="200" LowPicWidth="80" LowSize="14551" No="3" Original="https://images.icecat.biz/img/gallery_raw/31815437_6955.jpeg" OriginalSize="281165" Pic="https://images.icecat.biz/img/gallery/31815437_6955.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/31815437_6955.jpg" Pic500x500Height="500" Pic500x500Size="76841" Pic500x500Width="200" PicHeight="1000" PicWidth="401" ProductPicture_ID="25175290" Size="249242" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/31815437_6955.jpg" ThumbSize="1659" Type="ProductImage" UpdatedDate="2024-03-08 09:07:54"/>
   <ProductPicture LowPic="https://images.icecat.biz/img/gallery_lows/31815437_8406.jpg" LowPicHeight="200" LowPicWidth="82" LowSize="9315" No="5" Original="https://images.icecat.biz/img/gallery_raw/31815437_8406.jpeg" OriginalSize="240395" Pic="https://images.icecat.biz/img/gallery/31815437_8406.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/31815437_8406.jpg" Pic500x500Height="500" Pic500x500Size="57300" Pic500x500Width="206" PicHeight="1000" PicWidth="413" ProductPicture_ID="25175292" Size="208209" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/31815437_8406.jpg" ThumbSize="1119" Type="ProductImage" UpdatedDate="2024-03-08 09:07:54"/>
   <ProductPicture LowPic="" LowPicHeight="0" LowPicWidth="0" LowSize="0" No="999" Original="" OriginalSize="0" Pic="https://images.icecat.biz/img/feature_logo/1498-1295.png" Pic500x500="" Pic500x500Height="0" Pic500x500Size="0" Pic500x500Width="0" PicHeight="0" PicWidth="0" ProductPicture_ID="4309949491" Size="0" ThumbPic="https://images.icecat.biz/img/feature_logo_thumbs/1498-1295.png" ThumbSize="0" Type="FeatureLogo" UpdatedDate="" langid="4"/>
   <ProductPicture LowPic="" LowPicHeight="0" LowPicWidth="0" LowSize="0" No="999" Original="" OriginalSize="0" Pic="https://images.icecat.biz/img/feature_logo/91-5976.png" Pic500x500="" Pic500x500Height="0" Pic500x500Size="0" Pic500x500Width="0" PicHeight="200" PicWidth="200" ProductPicture_ID="4304089563" Size="24724" ThumbPic="https://images.icecat.biz/img/feature_logo_thumbs/91-5976.png" ThumbSize="0" Type="FeatureLogo" UpdatedDate="" langid="1"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2018-07-07 10:24:25" Description="Generated PDF" KeepAsURL="0" MultimediaObject_ID="0" Type="leaflet" UUID="00000000-0000-0000-0000-000000000000" langid="4" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="0" URL="https://icecat.biz/rest/product-pdf?productId=37909419&amp;lang=de" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated/>
  <SummaryDescription>
   <ShortSummaryDescription langid="4">Lenovo ThinkServer TD350, 2,1 GHz, E5-2620V4, 8 GB, DDR4-SDRAM, 0 GB, Turm (4U)</ShortSummaryDescription>
   <LongSummaryDescription langid="4">Lenovo ThinkServer TD350. Prozessorfamilie: Intel® Xeon® E5 v4, Prozessor-Taktfrequenz: 2,1 GHz, Prozessor: E5-2620V4. Speicherkapazität: 8 GB, Interner Speichertyp: DDR4-SDRAM, Speicherlayout: 1 x 8 GB. Gesamtspeicherkapazität: 0 GB, HDD Größe: 2.5&quot;, HDD Schnittstelle: Serial ATA III, Serial Attached SCSI (SAS). Ethernet/LAN, Verkabelungstechnologie: 10/100/1000Base-T(X). Optisches Laufwerk - Typ: DVD±RW. Stromversorgung: 550 W, Unterstützung für redundantes Netzteil. Gehäusetyp: Turm (4U)</LongSummaryDescription>
  </SummaryDescription>
  <Supplier ID="728" Name="Lenovo"/>
  <CatalogObjectCloud>
   <ProductPage QRCodeURL="https://qr.icecat.biz/coc/7971a252-27b4-42e8-bfc1-7394589cbe08" URL="https://coc.icecat.biz/7971a252-27b4-42e8-bfc1-7394589cbe08"/>
  </CatalogObjectCloud>
 </Product>
</ICECAT-interface>
