<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ICECAT-interface SYSTEM "https://data.icecat.biz/dtd/ICECAT-interface_response.dtd">
<!--source: Icecat.biz 2026-->
<!--Language ID: 74-->
<!--Version: v2-->
<ICECAT-interface xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://data.icecat.biz/xsd/ICECAT-interface_response.xsd">
 <Product Code="1" HighPic="https://images.icecat.biz/img/gallery/91984409_5027201339.jpg" HighPicHeight="528" HighPicSize="114379" HighPicWidth="1595" ID="101404605" LowPic="https://images.icecat.biz/img/gallery_lows/91984409_5027201339.jpg" LowPicHeight="66" LowPicSize="11978" LowPicWidth="200" Name="SR630" IntName="SR630" LocalName="" Pic500x500="https://images.icecat.biz/img/gallery_mediums/91984409_5027201339.jpg" Pic500x500Height="166" Pic500x500Size="35210" Pic500x500Width="500" Prod_id="7X02A0HUEA" Quality="ICECAT" ReleaseDate="" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/91984409_5027201339.jpg" ThumbPicSize="4033" Title="Lenovo ThinkSystem SR630 server Rack (1U) Intel® Xeon® Silver 4210R 2,4 GHz 32 GB DDR4-SDRAM 750 W" GeneratedIntTitle="Lenovo ThinkSystem SR630 server" GeneratedLocalTitle="Lenovo ThinkSystem SR630 server Rack (1U) Intel® Xeon® Silver 4210R 2,4 GHz 32 GB DDR4-SDRAM 750 W" BrandLocalTitle="">
  <CategoryFeatureGroup ID="10891" No="-80">
   <FeatureGroup ID="0">
    <Name ID="9550197" langid="74" Value="Dettagli tecnici"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1051" No="100">
   <FeatureGroup ID="1">
    <Name ID="7876974" langid="74" Value="Processore"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1049" No="90">
   <FeatureGroup ID="3">
    <Name ID="7876975" langid="74" Value="Memoria"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2697" No="20">
   <FeatureGroup ID="5">
    <Name ID="7876977" langid="74" Value="Display"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1053" No="50">
   <FeatureGroup ID="12">
    <Name ID="7876982" langid="74" Value="Connettività"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1055" No="-5">
   <FeatureGroup ID="14">
    <Name ID="7876984" langid="74" Value="Dimensioni e peso"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1056" No="10">
   <FeatureGroup ID="27">
    <Name ID="7876995" langid="74" Value="Gestione energetica"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2698" No="5">
   <FeatureGroup ID="28">
    <Name ID="7876996" langid="74" Value="Condizioni ambientali"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="1054" No="60">
   <FeatureGroup ID="35">
    <Name ID="7901242" langid="74" Value="Collegamento in rete"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8609" No="80">
   <FeatureGroup ID="47">
    <Name ID="7901251" langid="74" Value="Archiviazione"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="23800" No="-10">
   <FeatureGroup ID="67">
    <Name ID="7901245" langid="74" Value="Dati su imballaggio"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="2695" No="3">
   <FeatureGroup ID="76">
    <Name ID="7877035" langid="74" Value="Certificati di sicurezza"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="11644" No="15">
   <FeatureGroup ID="90">
    <Name ID="7877046" langid="74" Value="Software"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="7714" No="-20">
   <FeatureGroup ID="116">
    <Name ID="7877070" langid="74" Value="Contenuto dell'imballo"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="4192" No="40">
   <FeatureGroup ID="124">
    <Name ID="7877073" langid="74" Value="Slot espansione"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="53421" No="0">
   <FeatureGroup ID="143">
    <Name ID="7881173" langid="74" Value="Batteria"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8611" No="-100">
   <FeatureGroup ID="146">
    <Name ID="7881206" langid="74" Value="Altre caratteristiche"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10890" No="30">
   <FeatureGroup ID="148">
    <Name ID="7881258" langid="74" Value="Design"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="8610" No="70">
   <FeatureGroup ID="163">
    <Name ID="7885665" langid="74" Value="Grafica"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="12136" No="13">
   <FeatureGroup ID="183">
    <Name ID="7889320" langid="74" Value="Caratteristiche speciali del processore"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="10889" No="25">
   <FeatureGroup ID="184">
    <Name ID="7891161" langid="74" Value="Prestazione"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="20049" No="-70">
   <FeatureGroup ID="185">
    <Name ID="7891162" langid="74" Value="Caratteristiche"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="35829" No="0">
   <FeatureGroup ID="198">
    <Name ID="7894691" langid="74" Value="Dati logistici"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="59907" No="0">
   <FeatureGroup ID="232">
    <Name ID="7905695" langid="74" Value="Caratteristiche del fornitore"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="76092" No="0">
   <FeatureGroup ID="279">
    <Name ID="7921358" langid="74" Value="Sostenibilità"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <CategoryFeatureGroup ID="77982" No="0">
   <FeatureGroup ID="305">
    <Name ID="9550218" langid="74" Value="Impronta di carbonio"/>
   </FeatureGroup>
  </CategoryFeatureGroup>
  <Category ID="156">
   <Name ID="7907126" langid="74" Value="Server"/>
  </Category>
  <EANCode/>
  <FeatureLogo ID="1498" Feature_ID="2196" Value="Intel Xeon Silver" LogoPic="https://images.icecat.biz/img/feature_logo/1498-1295.png" Width="0" Height="0" Size="0">
   <Descriptions>
    <Description ID="6178" langid="1">Intel® Xeon® processors deliver cloud computing, real-time analytics, processing for your mission-critical business, and big data insights. Improve data center efficiency and reliability to handle any workload.</Description>
   </Descriptions>
   <FeatureLogoFeatures>
    <FeatureLogoFeature ID="2196">
     <FeatureLogoValues>
      <FeatureLogoValue ID="6638">Intel Xeon Silver</FeatureLogoValue>
     </FeatureLogoValues>
    </FeatureLogoFeature>
   </FeatureLogoFeatures>
  </FeatureLogo>
  <ReleaseDate/>
  <EndOfLifeDate/>
  <ReasonsToBuy/>
  <BulletPoints>
   <BulletPoint Value="Intel Xeon Silver 4210R (13.75MB Cache, 2.4GHz)" langid="5" No="1"/>
   <BulletPoint Value="32GB (2933MHz) DDR4-SDRAM (1 x 32)" langid="5" No="2"/>
  </BulletPoints>
  <GeneratedBulletPoints>
   <GeneratedBulletPoint Value="Intel® Xeon® Silver 4210R 2,4 GHz" langid="74" No="1"/>
   <GeneratedBulletPoint Value="32 GB 2933 MHz DDR4-SDRAM 1 x 32" langid="74" No="2"/>
   <GeneratedBulletPoint Value="Rack (1U) 750 W" langid="74" No="3"/>
  </GeneratedBulletPoints>
  <ProductBundled/>
  <ProductDescription ID="89769015" LongDesc="&lt;b&gt;Data center a prova di futuro&lt;/b&gt;&lt;br&gt; Lenovo offre soluzioni efficienti, economiche, affidabili e scalabili, combinando tecnologie leader di settore e le migliori offerte di prodotti software-defined al mondo, con Lenovo ThinkShield, XClarity e TruScale Infrastructure Services, per gestire il ciclo di vita associato alle esigenze dei data center. ThinkSystem SR630 offre supporto alle applicazioni di analisi dati, al cloud ibrido, alle infrastrutture iperconvergenti, alle applicazioni di videosorveglianza, ai processi di elaborazione ad alte prestazioni e tanto altro ancora. Per ottenere ulteriori informazioni sulle soluzioni SR630 che stanno cambiando la vita dei nostri clienti, visitate il sito: lenovo.com/case-studies&lt;br&gt;&lt;br&gt;&lt;br&gt;&lt;b&gt;Supporto ottimizzato per carichi di lavoro&lt;/b&gt;&lt;br&gt; La memoria Intel® Optane™ DC Persistent assicura un nuovo livello flessibile di memoria, progettato appositamente per i carichi di lavoro dei data center, in grado di offrire un'inedita combinazione di accessibilità, persistenza e capacità elevata. Questa tecnologia avrà un notevole impatto sul funzionamento dei data center nel mondo reale: Riduzione dei tempi di riavvio da minuti a pochi secondi; incremento di 1,2 volte della densità delle macchine virtuali; straordinario miglioramento delle capacità di replica dei dati con latenze 14 volte inferiori e IOPS 14 volte superiori, per dati persistenti integrati nell’hardware.* * Come risulta da test condotti internamente da Intel, agosto 2018.&lt;br&gt;&lt;br&gt;&lt;br&gt;&lt;b&gt;Storage flessibile&lt;/b&gt;&lt;br&gt; La linea Lenovo AnyBay offre la possibilità di scegliere fra diversi tipi di interfaccia drive all'interno dello stesso comparto drive: drive SAS, drive SATA o drive PCIe U.2 NVMe. L'opportunità di configurare alcuni comparti con drive SSD PCIe e usare i restanti comparti con drive SAS lascia aperta la strada alla possibilità di aggiornare il sistema sostituendo i drive SAS con altri drive SSD PCIe in futuro.&lt;br&gt;&lt;br&gt;&lt;br&gt;&lt;b&gt;Più potere alla gestione IT &lt;/b&gt;&lt;br&gt; Lenovo XClarity Controller è il motore di gestione integrato in tutti i server ThinkSystem, progettato per standardizzare, semplificare e automatizzare le attività fondamentali di gestione del server. Lenovo XClarity Administrator è un'applicazione virtualizzata che gestisce centralmente i server ThinkSystem, storage e networking, in grado di ridurre il tempo di provisioning fino al 95% rispetto all'operazione manuale. Inoltre, l'esecuzione di XClarity Integrator contribuisce a semplificare la gestione IT, accelerare il provisioning e contenere i costi, integrando perfettamente XClarity in un ambiente IT esistente." ManualPDFSize="0" ManualPDFURL="" MiddleDesc="" PDFSize="0" PDFURL="" ShortDesc="Intel Xeon Silver 4210R (13.75MB Cache, 2.4GHz), 32GB DDR4-SDRAM (2933MHz), Matrox G200e, LAN, 9350-8i, 750W" URL="https://www.lenovo.com/it/it/data-center/servers/racks/ThinkSystem-SR630/p/77XX7SRSR63" WarrantyInfo="" langid="5"/>
  <ProductFamily ID="68436" LowPic="" ThumbPic="">
   <Name ID="3553306" langid="1" Value="ThinkSystem"/>
  </ProductFamily>
  <ProductFeature Localized="0" ID="521769733" Local_ID="0" Value="Intel Xeon Silver" CategoryFeature_ID="11563" CategoryFeatureGroup_ID="1051" No="10100400" Optional="0" Presentation_Value="Intel® Xeon® Silver" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Intel® Xeon® Silver">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2196">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7879985" langid="74" Value="Famiglia processore"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769796" Local_ID="0" Value="Intel" CategoryFeature_ID="4443" CategoryFeatureGroup_ID="1051" No="10213006" Optional="0" Presentation_Value="Intel" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="Intel">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1013">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7879856" langid="74" Value="Produttore processore"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769731" Local_ID="0" Value="4210R" CategoryFeature_ID="1239" CategoryFeatureGroup_ID="1051" No="100398" Optional="0" Presentation_Value="4210R" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="4210R">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="47">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7900895" langid="74" Value="Modello del processore"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769730" Local_ID="0" Value="2.4" CategoryFeature_ID="73717" CategoryFeatureGroup_ID="1051" No="100396" Optional="0" Presentation_Value="2,4 GHz" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="2,4">
    <Measure ID="37">
     <Signs>
      <Sign ID="6747" langid="5"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11379">
    <Measure ID="37" Sign="">
     <Signs>
      <Sign ID="6747" langid="5"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7886912" langid="74" Value="Frequenza del processore"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521770132" Local_ID="0" Value="3.2" CategoryFeature_ID="72626" CategoryFeatureGroup_ID="1051" No="100395" Optional="0" Presentation_Value="3,2 GHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="3,2">
    <Measure ID="37">
     <Signs>
      <Sign ID="6747" langid="5"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="7978">
    <Measure ID="37" Sign="">
     <Signs>
      <Sign ID="6747" langid="5"><![CDATA[GHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7881154" langid="74" Value="Frequenza del processore turbo massima"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521770133" Local_ID="0" Value="13.75" CategoryFeature_ID="135262" CategoryFeatureGroup_ID="1051" No="100290" Optional="0" Presentation_Value="13,75 MB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="13,75">
    <Measure ID="19">
     <Signs>
      <Sign ID="6732" langid="5"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="10041">
    <Measure ID="19" Sign="">
     <Signs>
      <Sign ID="6732" langid="5"><![CDATA[MB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7886712" langid="74" Value="Cache processore"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769735" Local_ID="0" Value="Intel C624" CategoryFeature_ID="47167" CategoryFeatureGroup_ID="1051" No="100250" Optional="0" Presentation_Value="Intel® C624" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Intel® C624">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="436">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7877694" langid="74" Value="Chipset scheda madre"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769727" Local_ID="0" Value="1" CategoryFeature_ID="1280" CategoryFeatureGroup_ID="1051" No="100090" Optional="0" Presentation_Value="1" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="596">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7877707" langid="74" Value="Numero di processori installati"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521782785" Local_ID="0" Value="Y" CategoryFeature_ID="135019" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10196">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7886743" langid="74" Value="Execute Disable Bit"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521783169" Local_ID="0" Value="Y" CategoryFeature_ID="135032" CategoryFeatureGroup_ID="1051" No="100000" Optional="1" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10283">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7900381" langid="74" Value="Opzioni incorporate disponibili"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769754" Local_ID="0" Value="32" CategoryFeature_ID="73754" CategoryFeatureGroup_ID="1049" No="10100200" Optional="0" Presentation_Value="32 GB" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="32">
    <Measure ID="20">
     <Signs>
      <Sign ID="6733" langid="5"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11381">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6733" langid="5"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7886914" langid="74" Value="RAM installata"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769760" Local_ID="0" Value="DDR4-SDRAM" CategoryFeature_ID="4437" CategoryFeatureGroup_ID="1049" No="10100198" Optional="0" Presentation_Value="DDR4-SDRAM" Translated="0" Mandatory="1" Searchable="1">
   <LocalValue Value="DDR4-SDRAM">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="427">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7879728" langid="74" Value="Tipo di RAM"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769764" Local_ID="0" Value="Y" CategoryFeature_ID="20420" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1628">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7877794" langid="74" Value="Data Integrity Check (verifica integrità dati)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521770166" Local_ID="0" Value="2933" CategoryFeature_ID="31277" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="2933 MHz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="2933">
    <Measure ID="18">
     <Signs>
      <Sign ID="58004" langid="74"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="2900">
    <Measure ID="18" Sign="">
     <Signs>
      <Sign ID="58004" langid="74"><![CDATA[MHz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7880077" langid="74" Value="Velocità memoria"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521770159" Local_ID="0" Value="1 x 32" CategoryFeature_ID="73739" CategoryFeatureGroup_ID="1049" No="100000" Optional="0" Presentation_Value="1 x 32 GB" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="1 x 32">
    <Measure ID="20">
     <Signs>
      <Sign ID="6733" langid="5"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="11380">
    <Measure ID="20" Sign="">
     <Signs>
      <Sign ID="6733" langid="5"><![CDATA[GB]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7886913" langid="74" Value="Struttura memoria"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769777" Local_ID="0" Value="Y" CategoryFeature_ID="41696" CategoryFeatureGroup_ID="8609" No="100820" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="7335">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7900912" langid="74" Value="Supporto RAID"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769711" Local_ID="0" Value="N" CategoryFeature_ID="5723" CategoryFeatureGroup_ID="8609" No="100000" Optional="0" Presentation_Value="No" Translated="1" Mandatory="1" Searchable="0">
   <LocalValue Value="No">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1120">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7879929" langid="74" Value="Tipo drive ottico"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521770325" Local_ID="0" Value="0,1,5,6,10,50,60" CategoryFeature_ID="4659" CategoryFeatureGroup_ID="8609" No="100810" Optional="0" Presentation_Value="0, 1, 5, 6, 10, 50, 60" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0, 1, 5, 6, 10, 50, 60">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1470">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7877386" langid="74" Value="Livelli RAID"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521770328" Local_ID="0" Value="9350-8i" CategoryFeature_ID="166992" CategoryFeatureGroup_ID="8609" No="100800" Optional="0" Presentation_Value="9350-8i" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="9350-8i">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="26528">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7898240" langid="74" Value="Controller RAID supportati"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521770428" Local_ID="0" Value="8" CategoryFeature_ID="31275" CategoryFeatureGroup_ID="8609" No="100000" Optional="0" Presentation_Value="8" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2133">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7877395" langid="74" Value="Drive bay interni"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769786" Local_ID="0" Value="Y" CategoryFeature_ID="64539" CategoryFeatureGroup_ID="8610" No="100200" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9997">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7887804" langid="74" Value="Scheda grafica integrata"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769789" Local_ID="0" Value="Matrox G200e" CategoryFeature_ID="134996" CategoryFeatureGroup_ID="8610" No="100195" Optional="0" Presentation_Value="Matrox G200e" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="Matrox G200e">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="9016">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7885599" langid="74" Value="Modello scheda grafica integrata"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769792" Local_ID="0" Value="N" CategoryFeature_ID="56942" CategoryFeatureGroup_ID="1054" No="100013" Optional="0" Presentation_Value="No" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="No">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3239">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7880100" langid="74" Value="Wi-Fi"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769799" Local_ID="0" Value="Y" CategoryFeature_ID="41697" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1347">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7877771" langid="74" Value="Collegamento ethernet LAN"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769802" Local_ID="0" Value="10/100/1000Base-T(X)" CategoryFeature_ID="56945" CategoryFeatureGroup_ID="1054" No="100000" Optional="0" Presentation_Value="10/100/1000Base-T(X)" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="10/100/1000Base-T(X)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="747">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7879772" langid="74" Value="Tecnologia di cablaggio"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769708" Local_ID="0" Value="Rack (1U)" CategoryFeature_ID="1235" CategoryFeatureGroup_ID="10890" No="10113007" Optional="0" Presentation_Value="Rack (1U)" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Rack (1U)">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="734">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7879769" langid="74" Value="Tipo di case"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769715" Local_ID="0" Value="Black,Metallic" CategoryFeature_ID="256494" CategoryFeatureGroup_ID="10890" No="100100" Optional="0" Presentation_Value="Nero, Metallico" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Nero, Metallico">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="1766">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7880016" langid="74" Value="Colore del prodotto"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769718" Local_ID="0" Value="Y" CategoryFeature_ID="7105" CategoryFeatureGroup_ID="10890" No="100000" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="483">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7877699" langid="74" Value="Montaggio rack"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769721" Local_ID="0" Value="Y" CategoryFeature_ID="65773" CategoryFeatureGroup_ID="10890" No="100000" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10335">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7886759" langid="74" Value="Redundant fans support"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769724" Local_ID="0" Value="Y" CategoryFeature_ID="66072" CategoryFeatureGroup_ID="10890" No="100000" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10364">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7887986" langid="74" Value="Griglie"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769742" Local_ID="0" Value="XClarity Enterprise" CategoryFeature_ID="1247" CategoryFeatureGroup_ID="10889" No="113013" Optional="0" Presentation_Value="XClarity Enterprise" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="XClarity Enterprise">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="833">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7880557" langid="74" Value="Performance management"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769745" Local_ID="0" Value="Y" CategoryFeature_ID="64541" CategoryFeatureGroup_ID="10889" No="100000" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3574">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7901148" langid="74" Value="Modulo della piattaforma fidata (TPM)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769748" Local_ID="0" Value="Microsoft Windows Server 2016&#10;Microsoft Windows Server 2012 R2&#10;Red Hat Enterprise Linux 7.4&#10;Red Hat Enterprise Linux 7.3&#10;Red Hat Enterprise Linux 6.9 Server x64 Edition&#10;SUSE Linux Enterprise Server 12 SP3&#10;SUSE Linux Enterprise Server 12 SP2&#10;SUSE Linux Enterprise Server 11 for AMD64/EM64TSP4&#10;VMware vSphere 6.5 (ESXi) Update 1&#10;VMware vSphere 6.5 (ESXi)&#10;VMware vSphere 6.0 (ESXi) Update 3" CategoryFeature_ID="1289" CategoryFeatureGroup_ID="11644" No="100085" Optional="0" Presentation_Value="Microsoft Windows Server 2016&#10;Microsoft Windows Server 2012 R2&#10;Red Hat Enterprise Linux 7.4&#10;Red Hat Enterprise Linux 7.3&#10;Red Hat Enterprise Linux 6.9 Server x64 Edition&#10;SUSE Linux Enterprise Server 12 SP3&#10;SUSE Linux Enterprise Server 12 SP2&#10;SUSE Linux Enterprise Server 11 for AMD64/EM64TSP4&#10;VMware vSphere 6.5 (ESXi) Update 1&#10;VMware vSphere 6.5 (ESXi)&#10;VMware vSphere 6.0 (ESXi) Update 3" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="Microsoft Windows Server 2016&#10;Microsoft Windows Server 2012 R2&#10;Red Hat Enterprise Linux 7.4&#10;Red Hat Enterprise Linux 7.3&#10;Red Hat Enterprise Linux 6.9 Server x64 Edition&#10;SUSE Linux Enterprise Server 12 SP3&#10;SUSE Linux Enterprise Server 12 SP2&#10;SUSE Linux Enterprise Server 11 for AMD64/EM64TSP4&#10;VMware vSphere 6.5 (ESXi) Update 1&#10;VMware vSphere 6.5 (ESXi)&#10;VMware vSphere 6.0 (ESXi) Update 3">
    <Measure ID="29">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="2507">
    <Measure ID="29" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7880071" langid="74" Value="Sistema operativo compatibile"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521782711" Local_ID="0" Value="Y" CategoryFeature_ID="105685" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10195">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7887903" langid="74" Value="Tecnologia potenziata Intel SpeedStep"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521783384" Local_ID="0" Value="Y" CategoryFeature_ID="131546" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="18653">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7897535" langid="74" Value="Intel® Virtualization Technology for Directed I/O (VT-d)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521782915" Local_ID="0" Value="Y" CategoryFeature_ID="134979" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10200">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7897525" langid="74" Value="Tecnologia Intel® Trusted Execution"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521783090" Local_ID="0" Value="Y" CategoryFeature_ID="134981" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="10282">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7897537" langid="74" Value="Intel® VT-x with Extended Page Tables (EPT)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521783258" Local_ID="0" Value="Y" CategoryFeature_ID="135037" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="15741">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7897449" langid="74" Value="Intel® 64"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521783705" Local_ID="0" Value="Y" CategoryFeature_ID="135110" CategoryFeatureGroup_ID="12136" No="100000" Optional="1" Presentation_Value="Sì" Translated="1" Mandatory="0" Searchable="0">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="21759">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7897533" langid="74" Value="Tecnologia Intel® Virtualization (VT-x)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769817" Local_ID="0" Value="Y" CategoryFeature_ID="26567" CategoryFeatureGroup_ID="1056" No="10100200" Optional="0" Presentation_Value="Sì" Translated="1" Mandatory="1" Searchable="1">
   <LocalValue Value="Sì">
    <Measure ID="26">
     <Signs/>
    </Measure>
   </LocalValue>
   <Feature ID="3247">
    <Measure ID="26" Sign="">
     <Signs/>
    </Measure>
    <Name ID="7879013" langid="74" Value="Supporto Redundant power supply (RPS)"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769820" Local_ID="0" Value="750" CategoryFeature_ID="4718" CategoryFeatureGroup_ID="1056" No="100095" Optional="0" Presentation_Value="750 W" Translated="0" Mandatory="1" Searchable="0">
   <LocalValue Value="750">
    <Measure ID="44">
     <Signs>
      <Sign ID="6754" langid="5"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1242">
    <Measure ID="44" Sign="">
     <Signs>
      <Sign ID="6754" langid="5"><![CDATA[W]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7879957" langid="74" Value="Alimentazione"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769832" Local_ID="0" Value="50 - 60" CategoryFeature_ID="20442" CategoryFeatureGroup_ID="1056" No="100082" Optional="0" Presentation_Value="50 - 60 Hz" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="50 - 60">
    <Measure ID="36">
     <Signs>
      <Sign ID="6746" langid="5"><![CDATA[Hz]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1244">
    <Measure ID="36" Sign="">
     <Signs>
      <Sign ID="6746" langid="5"><![CDATA[Hz]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7877384" langid="74" Value="Frequenza di ingresso alimentatore"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769835" Local_ID="0" Value="5 - 45" CategoryFeature_ID="4441" CategoryFeatureGroup_ID="2698" No="100045" Optional="0" Presentation_Value="5 - 45 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="5 - 45">
    <Measure ID="65">
     <Signs>
      <Sign ID="6774" langid="5"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1112">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="6774" langid="5"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7879923" langid="74" Value="Intervallo temperatura di funzionamento"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769838" Local_ID="0" Value="-40 - 60" CategoryFeature_ID="1777" CategoryFeatureGroup_ID="2698" No="100044" Optional="0" Presentation_Value="-40 - 60 °C" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="-40 - 60">
    <Measure ID="65">
     <Signs>
      <Sign ID="6774" langid="5"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="757">
    <Measure ID="65" Sign="">
     <Signs>
      <Sign ID="6774" langid="5"><![CDATA[°C]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7879774" langid="74" Value="Intervallo di temperatura"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769842" Local_ID="0" Value="8 - 90" CategoryFeature_ID="1277" CategoryFeatureGroup_ID="2698" No="100035" Optional="0" Presentation_Value="8 - 90%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8 - 90">
    <Measure ID="64">
     <Signs>
      <Sign ID="6773" langid="5"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="703">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="6773" langid="5"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7879765" langid="74" Value="Range di umidità di funzionamento"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769845" Local_ID="0" Value="8 - 90" CategoryFeature_ID="12224" CategoryFeatureGroup_ID="2698" No="100033" Optional="0" Presentation_Value="8 - 90%" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="8 - 90">
    <Measure ID="64">
     <Signs>
      <Sign ID="6773" langid="5"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1383">
    <Measure ID="64" Sign="">
     <Signs>
      <Sign ID="6773" langid="5"><![CDATA[%]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7879978" langid="74" Value="Umidità"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769848" Local_ID="0" Value="0 - 3050" CategoryFeature_ID="17300" CategoryFeatureGroup_ID="2698" No="100005" Optional="0" Presentation_Value="0 - 3050 m" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="0 - 3050">
    <Measure ID="54">
     <Signs>
      <Sign ID="6763" langid="5"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="667">
    <Measure ID="54" Sign="">
     <Signs>
      <Sign ID="6763" langid="5"><![CDATA[m]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7879762" langid="74" Value="Altitudine di funzionamento"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769823" Local_ID="0" Value="435" CategoryFeature_ID="6245" CategoryFeatureGroup_ID="1055" No="100040" Optional="0" Presentation_Value="435 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="435">
    <Measure ID="24">
     <Signs>
      <Sign ID="6737" langid="5"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1649">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="6737" langid="5"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7880005" langid="74" Value="Larghezza"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769826" Local_ID="0" Value="750" CategoryFeature_ID="6241" CategoryFeatureGroup_ID="1055" No="100000" Optional="0" Presentation_Value="750 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="750">
    <Measure ID="24">
     <Signs>
      <Sign ID="6737" langid="5"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1650">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="6737" langid="5"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7880006" langid="74" Value="Profondità"/>
   </Feature>
  </ProductFeature>
  <ProductFeature Localized="0" ID="521769829" Local_ID="0" Value="43" CategoryFeature_ID="6244" CategoryFeatureGroup_ID="1055" No="100000" Optional="0" Presentation_Value="43 mm" Translated="0" Mandatory="0" Searchable="0">
   <LocalValue Value="43">
    <Measure ID="24">
     <Signs>
      <Sign ID="6737" langid="5"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
   </LocalValue>
   <Feature ID="1464">
    <Measure ID="24" Sign="">
     <Signs>
      <Sign ID="6737" langid="5"><![CDATA[mm]]></Sign>
     </Signs>
    </Measure>
    <Name ID="7879990" langid="74" Value="Altezza"/>
   </Feature>
  </ProductFeature>
  <ProductGallery>
   <ProductPicture IsMain="Y" LowPic="https://images.icecat.biz/img/gallery_lows/91984409_5027201339.jpg" LowPicHeight="66" LowPicWidth="200" LowSize="11978" No="1" Original="https://images.icecat.biz/img/gallery_raw/91984409_5027201339.jpeg" OriginalSize="114425" Pic="https://images.icecat.biz/img/gallery/91984409_5027201339.jpg" Pic500x500="https://images.icecat.biz/img/gallery_mediums/91984409_5027201339.jpg" Pic500x500Height="166" Pic500x500Size="35210" Pic500x500Width="500" PicHeight="528" PicWidth="1595" ProductPicture_ID="70326014" Size="114379" ThumbPic="https://images.icecat.biz/img/gallery_thumbs/91984409_5027201339.jpg" ThumbSize="4033" Type="ProductImage" UpdatedDate="2024-03-12 11:37:37"/>
   <ProductPicture LowPic="" LowPicHeight="0" LowPicWidth="0" LowSize="0" No="999" Original="" OriginalSize="0" Pic="https://images.icecat.biz/img/feature_logo/1498-1295.png" Pic500x500="" Pic500x500Height="0" Pic500x500Size="0" Pic500x500Width="0" PicHeight="0" PicWidth="0" ProductPicture_ID="4309949491" Size="0" ThumbPic="https://images.icecat.biz/img/feature_logo_thumbs/1498-1295.png" ThumbSize="0" Type="FeatureLogo" UpdatedDate="" langid="1"/>
  </ProductGallery>
  <ProductMultimediaObject>
   <MultimediaObject ContentType="application/pdf" Date="2023-01-10 11:58:25" Description="Generated PDF" KeepAsURL="0" MultimediaObject_ID="0" Type="leaflet" UUID="00000000-0000-0000-0000-000000000000" langid="74" Height="0" PreviewHeight="0" PreviewSize="0" PreviewUrl="" PreviewWidth="0" Size="0" URL="https://icecat.biz/rest/product-pdf?productId=101404605&amp;lang=it_ch" Width="0"/>
  </ProductMultimediaObject>
  <ProductRelated/>
  <SummaryDescription>
   <ShortSummaryDescription langid="74">Lenovo ThinkSystem SR630, 2,4 GHz, 4210R, 32 GB, DDR4-SDRAM, 750 W, Rack (1U)</ShortSummaryDescription>
   <LongSummaryDescription langid="74">Lenovo ThinkSystem SR630. Famiglia processore: Intel® Xeon® Silver, Frequenza del processore: 2,4 GHz, Modello del processore: 4210R. RAM installata: 32 GB, Tipo di RAM: DDR4-SDRAM, Struttura memoria: 1 x 32 GB. Collegamento ethernet LAN, Tecnologia di cablaggio: 10/100/1000Base-T(X). Alimentazione: 750 W, Supporto Redundant power supply (RPS). Tipo di case: Rack (1U)</LongSummaryDescription>
  </SummaryDescription>
  <Supplier ID="728" Name="Lenovo"/>
  <CatalogObjectCloud>
   <ProductPage QRCodeURL="https://qr.icecat.biz/coc/4fc08c59-5d5f-4828-8bb3-6b810c3905b4" URL="https://coc.icecat.biz/4fc08c59-5d5f-4828-8bb3-6b810c3905b4"/>
  </CatalogObjectCloud>
 </Product>